For combined walls (wide flange beams) with PZ/PZC (ball & socket) sheet piles

fits

  • PZ/PZC

works with

PZ 22, 27, 35, 40
PZC 12, 13, 14, 17, 18, 19, 25, 26, 28, 37, 39, 41

steel grade
ASTM Grade 50 or better,
MARINER™ steel
weight
~ 8.58 lb/ft

General weld guidelines for connectors

  1. All seams have a = 6 mm (~.236”).
  2. Both sides have a tip and toe welding continuously of 500 mm (~20.0”).
  3. Both sides are tack welded in the free length between tip and toe welding with 200 mm/m (~8”/3.28’). The distance from seam to seam is 800 mm (~31.5”) or less.
  4. In salt water the water side is continuously welded on the whole pile length. Rear side is as above in step #3.

Note: the above is for references purposes only and the welding design must be checked against other considerations such as anchor forces, shear forces and otherwise difficult driving conditions.